We’re at NCSEA in San Francisco, Oct 28–29 · Booth 110NCSEA · Booth 110 · Oct 28–29

Guide · Structural documents

Structural load path drawing checklist

A load path is the chain of members that carries each load from where it starts to the ground. On drawings it breaks in the gaps between sheets and between designers: a girder reaction with no post under it, a wall above with no wall below, or a supplier beam the engineer never sized.

Check the load path on drawings by following each load down, one support at a time: roof and floor framing to the wall, beam or girder that carries it, each large reaction to a sized post, each post to a footing, and each upper shear wall to a wall or designed transfer below. Then confirm that every member a supplier layout relies on is sized by someone, and that the loads each designer used are stated.

Where load paths break on drawings

Most load path problems are not calculation errors. They are hand-offs: the engineer’s framing plan stops at a member the truss or joist supplier designs, the supplier prints reactions that nobody carries further down, and a note on one sheet contradicts what the framing on another sheet does.

In the house floor truss submittal load path review, the truss layout said the floor carried no roof load, while two of its girders carried upper walls that held up the rafters. Girder reactions of several tons landed where the structural plan sized no post, and two long beams the layout relied on did not appear on the structural drawings at all.

Twelve questions for the load path

Work from the roof down, one level at a time. The CSV has columns for the location, the source references, the reviewer, the status, the decision and the closure evidence. It contains no design values; loads and member sizes come from the engineer of record and the delegated designers.

Structural load path drawing checklistSwipe or scroll sideways to read all columns.
Review areaOpen these sources togetherQuestion to resolve
Roof loads to their first supportRoof framing plan, truss layout, architectural roof plan, structural notesDoes every rafter, truss and roof beam bear on a wall, beam or girder the structural drawings show, for the roof covering the architectural sheets specify?
Walls that carry the roof or floors aboveUpper floor plans, framing plans, sections, truss or joist layoutsWhere an upper wall carries roof or floor loads, do the drawings give its line load to whoever designs the floor below it?
Notes against the framing they describeTruss or joist layout notes, structural notes, framing plansDoes any note say a member carries no roof, wall or equipment load that the framing plans show it carrying?
Girder and beam reactionsTruss or joist design drawings, beam calculations, structural plansDoes each large reaction land on a post, stud pack, column or wall the drawings size, rather than on typical framing?
Posts and columns down every floorFraming plans for each level, post and column schedules, foundation planDoes each post or column continue to the foundation or to a beam designed to carry it, at the same location on every plan?
Footings under concentrated loadsFoundation plan, footing schedule, slab and grade beam detailsIs there a footing, pad or thickened slab sized under each post, column and heavy bearing, not only under the perimeter walls?
Openings under bearing wallsDoor and window schedules, header and lintel schedules, elevations, framing plansIs every opening in a bearing wall spanned by a header or beam sized for the load above it and the actual opening width?
Supplier members in the engineer’s designTruss layout, beam layout, structural framing planIs every beam or girder a supplier layout relies on also sized on the structural drawings, or explicitly assigned to the supplier to design?
Shear walls stacked or transferredUpper and lower shear wall plans, architectural plans, transfer detailsDoes each upper shear wall stand over a lower wall, or over a beam designed and detailed to carry its shear and overturning?
Hold-downs and straps continuous to the foundationShear wall plans, hold-down schedule, floor-to-floor strap details, foundation planDoes each hold-down force continue through every floor to an anchor the foundation plan locates?
Collectors and diaphragm boundariesRoof and floor framing plans, collector and strap detailsWhere a diaphragm meets a shear wall or an offset, is the collector, strap or blocking that delivers the force shown?
Design loads stated for every designerStructural design notes, delegated design requirements, specificationsDo the notes state the dead, live, wind and other loads that the truss, joist and connector designers must design to?

Mark a row not applicable only after recording why. A one-story building still has reactions, posts and footings to follow.

Follow the lateral path too

Wind and seismic loads follow their own path: diaphragm, collector, shear wall, hold-down, anchor, foundation. The common break is an upper shear wall with nothing designed under it. The same review found a second-floor shear wall standing over an open kitchen, with no wall, beam or transfer detail below. The two-story house roof load and shear wall review of the same house found an interior shear wall standing on the thin slab beside its grade beam. The wood shear wall drawing checklist covers those walls in detail.

Check what each designer was told

Delegated designers design to the loads the drawings give them. Check that the structural notes state the floor and roof loads, and that any heavy finish, equipment or wall above is given as a load to the designer of the member that carries it. The wood truss drawing review checklist covers the truss package itself, and delegated design explained covers who is responsible for what. Use the calculations versus drawings checklist to confirm the calculations used the same loads the drawings show.

Where Groundbook fits

Groundbook compares the structural drawings, supplier layouts, truss or joist design drawings, architectural drawings and calculations you upload, and returns potential conflicts with links to each source, such as a girder reaction on a truss drawing with no post on the structural plan beneath it. It does not calculate loads, size members or decide code compliance. Each finding is a question for the engineer of record and the delegated designer. See cross-discipline coordination review for the workflow.

Questions, answered

FAQs

What is a load path in construction drawings?

The chain of members, connections and foundations that carries each load to the ground. On drawings, every link in that chain must be shown and sized on some sheet.

How do you check a load path on a set of drawings?

Start at the roof and follow each load to its support, level by level, to the footings. Record any reaction, wall or beam with nothing designed beneath it.

Who is responsible for the load path?

The engineer of record is responsible for the overall structure. Delegated designers, such as truss suppliers, design their own members to the loads they are given.

Can a truss supplier’s layout break the load path?

Yes, when it relies on beams, posts or connections that no one designs. Each member and connection the layout assumes needs a size from the engineer or the supplier.

Keep exploring

Continue your review

Structural drawing review checklist

Review structural notes, framing plans, schedules, details, and support interfaces with a practical checklist, worked example, and free editable CSV.

Explore

Wood truss drawing review checklist

Check wood truss layouts and truss design drawings against the architectural and structural sheets: loads, bearings, headers, uplift and bracing. Free CSV.

Explore

Wood shear wall drawing checklist

Check wood shear wall drawings from plan to anchor: walls on the architectural plans, openings, foundations, hold-downs, nailing and connectors. Free CSV.

Explore

Trace structural calculation criteria into the drawings

Compare structural calculation references, loads, member labels and schedules with issued plans and details. Includes an editable consistency checklist.

Explore

Geotechnical report vs. foundation drawings checklist

Check foundation, basement, shoring and waterproofing drawings against the geotechnical report’s recommendations. 12 review prompts and a free CSV.

Explore

House floor truss submittal load path

A review of a two-story house’s floor truss package against its structural design finds girder loads, beams and hangers that no engineer’s sheet carries.

Explore

Two-story house roof load and shear walls

A permit review of a two-story house finds roof rafters designed for a lighter roof than the slate tile specified and a shear wall standing on the slab.

Explore

Cross-discipline coordination

Find potential conflicts across architectural, structural, and MEP drawings. Review levels, openings, equipment, and references with linked document evidence.

Explore

Bring your next set into focus

Set up a review or talk through your project with our team.

Follow every girder, post and shear wall down to its footing