Guide · Specifications and drawings · 09 22 00

Check non-structural metal framing specifications against partition, furring, and drywall ceiling drawings

UFGS Section 09 22 00 Supports for Plaster and Gypsum Board, a NAVFAC-prepared guide specification reissued after a complete review and update in August 2024, covers the non-load-bearing cold-formed steel framing, furring, and ceiling suspension systems that receive lath, plaster, stucco, and gypsum board. Its opening note limits it to partitions within a stated height and lateral load range whose top lateral support is detailed on the drawings, and its drawing note asks for the location of each type of framing, furring, or suspension system, member spacing and gauge where they differ from the referenced standard, and seismic restraint. Its articles cover AISI S220 framing and coatings, a standard or heavier stud option for walls carrying cabinetwork and equipment, slip-type head joints and firestop tracks, fire-retardant-treated backing, sound isolation clips, one-piece header and jamb studs, partial-height wall connectors, penetration barrier mesh, column furring to UL designs, Z-furring with insulation, and a drywall suspension grid with its moldings, hangers, and clips.

Start by sorting the partition types: confirm that every wall framed under the issued Section 09 22 00 falls within the height and lateral load range its opening note sets and has its top lateral support detailed, and that taller, more heavily loaded, or exterior walls are assigned to Section 05 40 00 or a designed system. Then check that the drawings show the location of each framing, furring, and suspension type, the stud thickness for walls carrying cabinetwork and equipment, the head-of-wall joint and the deflection it absorbs, backing locations, opening framing, partial-height wall anchorage, column furring designs, Z-furring depth against the insulation, and the drywall ceiling grid, hangers, and seismic restraint, and that the gaps the section leaves have been edited.

Assemble the review package

Gather the floor plans with partition tags, the partition type schedule with stud depth, thickness, spacing, limiting height, and head condition, the wall sections and head-of-wall details at slabs, decks, and beams, the reflected ceiling plans with gypsum board ceilings, soffits, bulkheads, and access panels, the ceiling sections and drywall grid details, the interior elevations showing cabinetwork, shelving, handrails, grab bars, monitors, and wall-hung equipment, the door schedule and frame details, the life safety plan with rated walls and their UL designs, the column furring and fireproofing details, the exterior wall sections with Z-furring and insulation, any security or penetration-resistant wall types, the structural notes on seismic design category, risk category, and floor and roof deflection, and the issued Section 09 22 00 with Sections 09 29 00, 05 40 00, 09 51 00, 13 48 73, and the lath, plaster, or stucco sections the project uses. Follow one partition type from its bottom track to its head and one ceiling from its hangers to its perimeter before assuming the others match.

WBDG publishes UFGS 09 22 00: Supports for Plaster and Gypsum Board as a public guide-specification reference (accessed November 9, 2026). Use your project’s issued specification and amendments for the actual comparison; the guide specification does not automatically govern your project. The checklist below is an original suggested review workflow, not a reproduction of the UFGS requirements.

Eight checks to run against the issued set

Use one record per location or system. The CSV contains the same eight prompts plus fields for source revisions, observed evidence, the review owner, the decision, and closure references.

Eight specification-to-drawing checksSwipe or scroll sideways to read all columns.
CheckSources to compareQuestion to resolve
Height, lateral load, and top support limitsOpening note (partition height and lateral load limits; top lateral support specifically detailed on the drawings) + Section 05 40 00 Load-Bearing Cold-Formed Metal Framing note (the same limits; special consideration beyond them) + Non-load Bearing Wall Framing installation (ASTM C754) + partition type schedule + wall sections and head details + structural notesDoes each partition type stay within the height and lateral load range the opening note sets, counting tall gymnasium, warehouse, lobby, and mechanical room walls and any wall that carries pressurization or hanging loads, is the top lateral support detailed for every type, as the note requires, rather than left to the installer, and are walls beyond that range given a designed stud on the schedule and moved to Section 05 40 00 or a framing engineer, since nothing in 09 22 00 covers them?
Stud thickness where walls carry cabinetwork and equipmentNon-load Bearing Wall Framing and Furring note and thickness bracket (standard thickness with a heavier stud for walls supporting wall-hung items, or a heavier stud throughout for medical, dental, and similar facilities) + Section 09 29 00 abuse-resistant board note (heavier framing coordinated with 09 22 00) + interior elevations + partition type scheduleWhich thickness option did the specifier keep, and do the partition types match it, where the first option is kept, do the interior elevations identify every wall that carries cabinetwork, shelving, handrails, grab bars, monitors, or equipment so the heavier stud reaches those walls, and do walls finished with abuse-resistant board use the heavier framing the 09 29 00 note asks for?
Head-of-wall slip joints, firestop tracks, and deflectionSlip-Type Head Joints item (slotted deflection track, clip system with a bracketed minimum movement, or single long-leg track with bridging near the top) + Firestop Tracks item and installation paragraphs + Firestop Track paragraph under the lath systems + structural deflection data + head-of-wall details + rated wall types and joint systemsDoes each head-of-wall detail use one of the three slip-type options and say which, is the vertical movement it allows at least the deflection the structural notes give for the slab, deck, or beam above, does each rated wall use a firestop track whose head-of-wall joint system matches its listing, and since PART 3 has firestop track paragraphs but no installation paragraph for the slip-type head joints, do the details or manufacturer data give the fastening that leaves the joint free to move?
Backing, framed openings, and partial-height wallsBacking Plate item (fire-retardant-treated wood blocking) and installation paragraph (manufacturer’s instructions) + Framed Openings item (one-piece header and jamb studs) and installation paragraph (approved design) + Partial Wall Framing Connection item and installation paragraph (anchor to the floor as designed by the Engineer of Record; sealer gasket) + interior elevations + door schedule and frame details + structural detailsDo the drawings show where backing goes and whether it is the fire-retardant-treated wood the item describes or the steel plate its title suggests, and since the section cites no treatment standard or Division 06 section for that wood, which issued document covers it, do heavy doors and frames get the one-piece header and jamb studs, and whose “approved design” governs them, since the section has no design submittal, and does every half-height wall, counter wall, or guard wall show the floor anchorage and connector the Engineer of Record is to design?
Furring at columns, masonry, and insulated exterior wallsFurring Structural Steel Columns items (studs, or UL-listed clips and support angles; UL design numbers indicated or chosen for the rating indicated) + Z-Furring Channels with Wall Insulation items and note (furring depth coordinated with the insulation thickness) + Suspended and Furred Ceiling Systems and Wall Furring for lath + life safety plan + column furring and fireproofing details + exterior wall sections + energy compliance documentsDoes every furred steel column carry the UL design number the installation paragraph points to, or a rating from which one can be chosen, and does that design agree with the fireproofing details, is the Z-furring depth kept in the section the one that holds the insulation thickness and R-value the wall sections and energy documents use, and are the masonry and concrete walls to receive furring the ones the fastening bracket names?
Drywall ceiling grid, hangers, and perimeterSuspension Systems Structural Classification (heavy-duty classification under ASTM C635/C635M; note-like text on closer wires and on deflection) + Components (main beams, cross tees, wall moldings, hangers, carrying channel splices, clips) + Suspension Systems installation (ASTM C635/C635M called the installation standard; hanger wire spacing by local practice; manufacturer representative; interior or exterior use) + Suspended and Furred Ceiling Systems installation (ASTM C754) + Section 09 51 00 (no hangers from the underside of steel deck; ASTM C636/C636M) + reflected ceiling plans and ceiling sectionsDo the reflected ceiling plans say which gypsum board ceilings use the drywall grid and which use furring channels or studs, do the ceiling sections show where hangers attach to structure and whether they may hang from steel deck, which Section 09 51 00 forbids for acoustical ceilings and this section does not address, are added hangers shown at light fixtures, grilles, and access doors, are exterior soffits on the grid given the coating and wind criteria the section leaves out, and has the specifier replaced the installation paragraph’s reliance on local practice and a manufacturer representative with stated requirements and corrected its call to ASTM C635/C635M as the installation standard, which the References article titles a manufacture, performance, and testing standard?
Seismic restraint of partitions and ceilingsDrawing note item on seismic restraint (seismic zones; ANSI/AISC 341 and UFC 3-301-01) + Materials article bracketed sentence (support systems and attachments under ANSI/AISC 341 or UFC 3-301-01 in seismic zones) + Section 13 48 73 component lists (partitions) + Section 09 51 00 seismic details (UFC 3-301-01 and ASTM E580/E580M) + structural notes (seismic design category, risk category) + partition head and ceiling bracing detailsWhere the structural notes put the building in a seismic design category that calls for bracing, do the drawings show partition top bracing and drywall ceiling bracing and perimeter details, has the specifier replaced the seismic zone wording, which predates seismic design categories, and the pointer to ANSI/AISC 341, the AISC seismic provisions for structural steel buildings, with the nonstructural criteria the project applies through UFC 3-301-01, and is it clear whether partitions are on the component list of Section 13 48 73 and who designs their bracing?
Sound, security mesh, coatings, and submittalsSound Isolation Clips item + Sound-Rated Partitions paragraph (under the lath systems only) + Drywall Penetration Barrier Mesh item and installation paragraph (layout approved by the General Contractor) + Materials and Protective Coating items and coating note (high-humidity environments) + sealer gasket sentences in two installation paragraphs + SD-02 Metal Support Systems, SD-03 Product Data, and the SD-04 Evaluation Reports paragraph + Section 09 29 00 Shaftwall Liner Panel note + partition types, security wall types, and wet room locationsDo sound-rated partition types show the clips, resilient channels, and sealant they rely on, since the only sound-rated framing paragraph sits under the lath systems, are the walls and ceilings that need penetration barrier mesh shown, with the layout approved by the contracting officer rather than the “General Contractor”, has the specifier settled which galvanized coating applies, since the Protective Coating item names two different minimum coatings in consecutive sentences, and the heavier coating for showers, kitchens, and other humid rooms, is a sealer gasket product added for the bottom track the installation paragraphs require, is the evaluation report requirement moved into the submittal list, since UFGS 01 33 00 uses SD-04 for samples, and where Section 09 29 00 specifies shaftwall, have shaftwall studs been added here, as its note asks?

Worked example: tall gym walls under a partition tag, unbacked exam room cabinets, and a ceiling hung from deck

Illustrative example: a single-story medical and dental clinic addition at an installation in a moderate seismic area uses one interior partition type throughout, framed under the issued Section 09 22 00 with the first stud thickness option kept, and a gypsum board ceiling on a drywall grid in the corridors and waiting areas. The physical therapy gym walls run well above the height range the opening note sets, but they carry the same partition tag as the exam rooms. The interior elevations show upper cabinets, monitors, and dental equipment arms on the exam room walls, but the partition type gives no heavier stud and no backing. The head-of-wall detail shows a slotted deflection track under the steel deck without the deflection it must absorb, the ceiling section hangs the drywall grid from the underside of the steel deck, which Section 09 51 00 forbids for the acoustical ceilings in the same building, and the specification keeps the ANSI/AISC 341 seismic sentence while Section 13 48 73 lists partitions among its braced components.

Ask the architect to give the gym walls their own partition type with a designed stud and top support, moved to Section 05 40 00 or the framing engineer’s scope, to keep the heavier stud where cabinetwork and equipment hang or mark every such wall, and to locate backing on the interior elevations. Ask the structural engineer for the deck and beam deflection the head of wall must take and for a statement of how the partitions and the drywall ceiling are braced and where hangers may attach. Ask the specifier to replace the ANSI/AISC 341 sentence with the nonstructural criteria the project applies, to coordinate the partition entry in Section 13 48 73, and to add the sealer gasket and the slip joint and hanger installation requirements the section leaves out.

Avoid a false conflict

Section 09 22 00 covers non-load-bearing framing, furring, and drywall ceiling suspension for lath, plaster, stucco, and gypsum board. Its notes send load-bearing framing to Section 05 40 00 Cold-Formed Metal Framing and acoustical ceiling suspension to Section 09 51 00 Acoustical Ceilings; the board, accessories, joint treatment, and rated assemblies follow Section 09 29 00 Gypsum Board and the gypsum board guide, lath follows Section 09 22 36 Lath, plaster and stucco follow Sections 09 23 00 and 09 24 23, partition seismic attachment may be listed in Section 13 48 73, and joints and penetrations in rated walls follow Section 07 84 00 Firestopping, all Active on WBDG; check those before calling a requirement missing. Section 09 29 00 tells the specifier to edit this section to add shaftwall liner panel studs and to coordinate heavier framing for abuse-resistant board, so a project with shaftwall or abuse-resistant board should show both edits here. The opening note’s height and lateral load limits tell the specifier when to use the section; they do not size the studs, and stud sizes beyond them, bracing, and seismic restraint are decisions for the architect and the structural engineer. The section lists UFC 3-301-01 as the digital version, while WBDG shows the 2023 edition with Change 6 of January 2026; confirm the version your task order invokes. The current guide section cites ANSI/AISC 341, AISI S220, ASTM A653, C635, C754, C841, and C847, ICC-ES AC98, UFC 3-301-01, and the UL Fire Resistance Directory; confirm the editions your project invokes.

When requirements disagree, follow the project’s document-control and clarification process. Do not assume that drawings always override specifications, or the reverse. Identify the exact sources and request an authorized decision.

Close the issue across the affected documents

Record the location or tag, drawing and specification references, issue dates, observed difference, and the decision needed. Assign an owner and keep the item open until the response identifies the governing requirement. Check the revised drawings and specification references together; a response email alone may leave the issued package inconsistent.

For the overall process, use the guide to drawing and specification conflicts. Mark an inapplicable checklist row with a reason, and distinguish a verified correction from a question that still needs design information.

Where Groundbook fits

Groundbook’s drawing and specification review helps investigate potential disagreements in the documents you supply. Include the relevant specification sections and drawing references, then verify the cited evidence with the responsible reviewers before acting on a finding.

Questions, answered

FAQs

What should a non-structural metal framing specification review compare?

Compare height, lateral load, and top support limits, stud thickness where walls carry cabinetwork and equipment, head-of-wall slip joints, firestop tracks, and deflection, backing, framed openings, and partial-height walls, furring at columns, masonry, and insulated exterior walls, the drywall ceiling grid, hangers, and perimeter, seismic restraint of partitions and ceilings, and sound, security mesh, coatings, and submittals.

What must the drawings show under UFGS 09 22 00?

The current UFGS 09 22 00 Supports for Plaster and Gypsum Board on WBDG asks the drawings to show the location of each type of metal framing, furring, and suspension system, member spacing and gauge where they differ from the referenced standard, and seismic restraint, and its opening note expects the lateral support at the top of each wall to be detailed. Its articles add slip-type head joints, firestop tracks, backing, penetration barrier mesh, and partial-height wall connections where indicated, and UL design numbers for furred columns. UFGS numbers are DoD guide specification numbers, not universal MasterFormat titles, and your project’s issued specification governs.

When does a partition need Section 05 40 00 instead of 09 22 00?

The opening note of UFGS 09 22 00 limits it to partitions within a stated height and lateral load range whose top support is detailed, and the load-bearing framing note of UFGS 05 40 00 says walls beyond that range need special consideration beyond the standard stud. Load-bearing walls, exterior studs that carry wind, and tall or heavily loaded partitions therefore need a designed stud and should be assigned to 05 40 00 or a framing engineer; the architect and the structural engineer decide which walls those are.

How is this different from the gypsum board guide?

The gypsum board guide follows the board: type, layers, fire and sound ratings, head-of-wall rating, and finish level for each partition type. This page follows what holds the board up under UFGS 09 22 00: which walls the section may frame, stud thickness for wall-hung loads, slip joints and deflection, backing and opening framing, partial-height walls, column and Z-furring, the drywall ceiling grid and hangers, and seismic restraint.

Can Groundbook check partition and ceiling framing against Section 09 22 00?

Groundbook compares the drawing set with the reference documents you upload, such as your issued Section 09 22 00, Section 09 29 00, the structural notes, manufacturer data, and licensed codes or standards you hold, and links each potential disagreement to both sources. It has no built-in code library and does not calculate limiting heights, deflections, hanger spacing, or seismic bracing, design the framing, certify compliance, or approve a submittal. Each finding is a question for the architect, the structural engineer, or the contracting officer.

Keep exploring

Continue your review

Check gypsum board specifications against partition types

Compare partition-type gypsum board layers, framing, fire and sound ratings, and joint treatment across drawings and specifications.

Explore

Check cold-formed metal framing specifications against framing plans, wall sections, and details

Compare delegated design criteria, studs, tracks, clips, bridging, headers, slide connections, and sealed submittals with UFGS 05 40 00.

Explore

Check acoustical ceiling specifications against drawings

Compare acoustical ceiling grid, tile, seismic bracing, and MEP coordination across reflected ceiling plans and specifications. Editable CSV included.

Explore

Reflected ceiling plan review checklist

Coordinate reflected ceiling plans with lighting, HVAC, fire protection, sections, and access requirements using a practical drawing review checklist.

Explore

ASTM E1966 and UL 2079 fire-resistive joint system review

Check head-of-wall, wall-to-wall, and curtain wall edge joints against tested systems: ASTM E1966-24, UL 2079, ASTM E2307, and details.

Explore

Check nonstructural seismic control specifications against drawings

Compare seismic design criteria, who designs supports, component lists, designated seismic systems, anchors, and special inspection with UFGS 13 48 73.

Explore

AISI S240 cold-formed steel structural framing review of drawings and delegated design

Review cold-formed steel framing against AISI S240-20, free from AISI: editions, structural vs. nonstructural walls, delegated design, members, connections.

Explore

Check cement stucco specifications against exterior elevations, wall sections, and details

Compare stucco lath, framing, weather barrier, control joints, accessories, terminations at openings and grade, soffits, and finish coats with UFGS 09 24 23.

Explore

Check insulation specifications against wall sections

Review insulation type, thickness, thermal-value basis, continuity, and adjacent materials across wall sections and specifications. Editable CSV included.

Explore

Check wood casework specifications against drawings

Compare casework grade, laminate and finish, countertop material, and accessible clearances against drawings. Includes an editable checklist.

Explore

School science building coordination

A school science building review finds conflicting column positions, wall systems and elevator requirements across drawings, design briefs and addenda.

Explore

Drawings vs. specifications

Compare drawing requirements with specifications, schedules, and controls. Find potential equipment, material, and scope inconsistencies with Groundbook AI.

Explore

Bring your next set into focus

Set up a review or talk through your project with our team.

Check your partition, furring, and ceiling framing against Section 09 22 00

Trusted by hundreds of professionals