We’re at NCSEA in San Francisco, Oct 28–29 · Booth 110NCSEA · Booth 110 · Oct 28–29

Guide · Specifications and drawings · 09 65 66

Check resilient athletic flooring specifications against finish plans, game line plans, slab joints, and equipment layouts

UFGS Section 09 65 66 Resilient Athletic Flooring, a USACE-prepared guide specification issued in August 2016 and changed in August 2018, covers indoor-outdoor carpeting, rubber composition tile, rubber poured-in-place flooring, sheet rubber and sheet vinyl composition flooring, and urethane poured-in-place flooring for weight rooms, running tracks, recreational areas, aerobic centers, and multi-purpose gym floors, with resilient mat underlay, adhesives, crack filler, edging strips, primer, game line material, wall base, and sealants. It asks for ASTM F2772 athletic performance and shock absorption results, an ASTM E648 fire test, manufacturer and installer qualifications, shop drawings of borders, patterns, and seams, and manufacturer and installer warranties. Part 3 covers slab preparation, the moisture check, installation of each floor type, line marking, and protection. It works with Sections 09 06 00, 07 92 00, 03 30 00, and 01 33 00.

Start with the Part 2 note of the issued Section 09 65 66: each flooring type gets its own paragraph and symbol, and the same symbol must key it to its rooms on the drawings, so confirm that every weight room, track, and multi-purpose floor on the finish plan points to one kept type. Then check that the required performance class suits each room’s sport, that thickness and underlay match the floor heights at doors and adjacent floors, that game lines and equipment anchor plates are drawn, and that the moisture test and warranty conditions agree.

Assemble the review package

Gather the finish plans and finish schedule with floor type symbols, the room program for the fitness, weight, track, aerobic, pool, and multi-purpose spaces, the game line plan, the equipment plan with floor sockets and anchor plates, the electrical floor box and under-floor conduit layout, the structural slab plans with joints and any slab recesses, floor transition and threshold details, the base schedule, the life safety plan with interior finish requirements, and the issued Section 09 65 66 with Sections 09 06 00, 07 92 00, 03 30 00, and 01 33 00 and any Division 11 athletic equipment section. Follow one room from its slab and joints up through underlay, flooring, lines, and base before assuming the others match.

WBDG publishes UFGS 09 65 66: Resilient Athletic Flooring as a public guide-specification reference (accessed November 18, 2026). Use your project’s issued specification and amendments for the actual comparison; the guide specification does not automatically govern your project. The checklist below is an original suggested review workflow, not a reproduction of the UFGS requirements.

Eight checks to run against the issued set

Use one record per location or system. The CSV contains the same eight prompts plus fields for source revisions, observed evidence, the review owner, the decision, and closure references.

Eight specification-to-drawing checksSwipe or scroll sideways to read all columns.
CheckSources to compareQuestion to resolve
Floor types and the finish plan keysPart 2 note (separate paragraph and symbol for each flooring type; the same symbols key types to locations listed or shown on the drawings; types chosen for a specific use such as carpet for pool areas and pro shops or rubber tile for weight rooms) + Indoor-Outdoor Carpeting, Rubber Composition Tile, Rubber Poured-In-Place, Sheet Rubber, Sheet Vinyl, and Urethane Poured-In-Place, each “Type [A] [_____]” + Part 1 note (indoor athletic rooms; hardwood preferable for basketball, handball, and racquetball courts; rubber floorings also outdoors) + Section 09 06 00 + finish plans and scheduleDoes every athletic room on the finish plan carry a type symbol that matches one kept paragraph, have the unused types been deleted with their submittals and certifications, and has the owner confirmed a resilient floor rather than wood for any basketball or racquetball court the note steers toward hardwood?
Athletic performance and shock absorptionPerformance Properties (ASTM F2772 certification for the “category/classification specified for this project”) + Athletic Performance Properties (one F2772 performance level for force reduction and ball rebound, with no bracket) + Shock Absorption (results from certified laboratories; “EN and DIN” tests from European laboratories, none listed in References) + SD-06 Laboratory Test Results + room programHas the specifier stated which F2772 classification each floor type must meet, does the single fixed level make sense for a weight room, track, or carpeted pro shop where ball rebound does not apply, and which EN or DIN test, if any, will be accepted in place of the ASTM method?
Fire performance and indoor air qualityFire Performance (“Provide fire performance test results”, no test named) + Fire Test Characteristics (ASTM E648 class, tested by an agency acceptable to the authority having jurisdiction) + Indoor Air Quality Certifications (FloorScore, UL 2818, SCS, CRI programs by product) + CDPH and SCAQMD limits for poured floors, adhesives, primer, and game line materials + Wall Base note (IAQ sentences only for offices or classrooms) + life safety plan and the adopted codeDoes the interior floor finish classification required by the code for each corridor, exit, and athletic room match the radiant flux class the section asks for, does the Fire Performance paragraph say which test it means, and are the indoor air quality certifications assigned to every kept product?
Slab, joints, and moisturePart 3 note (avoid expansion joints under the flooring by placing them at the perimeter; shrinkage compensating concrete for large areas such as gymnasiums) + Preparation (cured and dry; no curing agents, sealers, or hardeners; flatness tolerance; cracks and construction joints filled; expansion joints sealed to ASTM C920 and kept working) + Sealants (Section 07 92 00) + Moisture Test (manufacturer’s range, no method named) + Manufacturer’s Warranty (moisture limits by ASTM F2170 and ASTM F1869, the emission rate printed without its area and time basis) + structural slab and joint plans, Section 03 30 00Do the slab joint plans keep expansion joints out of the athletic floor area, does Section 03 30 00 forbid curing compounds and sealers on those slabs, which moisture test and limit will be run before installation, and has the specifier completed the emission rate in the warranty clause so it can be measured?
Thickness, underlay, and floor heightsRubber Composition Tile, Sheet Rubber, Sheet Vinyl, and Urethane thickness brackets + Rubber Poured-In-Place (no thickness given) against Part 3 (“the required thickness”) + Urethane note (range of thicknesses; coordinate with the manufacturer) + Resilient Mat Underlay and note (thickness blank; used under polyurethane wear coat, sheet rubber, or vinyl sheet systems) + Edging Strips + beveled transfer border “where required” + floor transition and threshold detailsHas the specifier given a thickness for rubber poured-in-place flooring and for the mat underlay, does the total system height match a slab recess or an edging strip at each door and adjacent floor, and do the transition details show the beveled border or edging strip the section supplies?
Seams, borders, patterns, and installersShop Drawings (installation details, borders, patterns, and floor seam locations; SD-02 “Approved Detail Drawings”) + Sheet Vinyl seams and Hot-Welded Seams + Sheet Rubber seams + Rubber Composition Tile with or without adhesive (note; interlocking ears; transfer border) + Manufacturer and Installer Qualifications + Adhesive Application + sheet vinyl friction tested by ASTM D1894, titled in References for plastic film and sheeting + finish plansDo the finish plans show the borders, patterns, and seam layout the shop drawings must follow, is tile laid with or without adhesive by one bracket, are hot-welded seams kept where the room is wet or must be cleanable, and does the slip resistance the owner expects rest on a test suited to sport flooring?
Game lines, anchor plates, and equipmentCoordination (layout with other gymnasium equipment) + Application With Adhesive (submit drawings showing game lines, anchor plate assemblies, floor outlets, and under-floor conduit or raceways, required only in this tile paragraph) + Game Line Material (as recommended by the flooring manufacturer) + Line Marking and Finishing (according to approved detail drawings) + Division 11 equipment section + equipment plan, electrical floor boxes, game line planDoes a game line plan give courts, colours, and widths for each floor that gets lines, do equipment anchor plates and floor outlets appear on the plans with a detail through the athletic floor, and has the specifier moved the game line and anchor plate drawing requirement into Shop Drawings so it covers every floor type, not only adhesive-set tile?
Base, colour, storage, warranty, and protectionWall Base (rubber or vinyl, straight or coved; Part 3 installs only “Molded Rubber Base”) + Manufacturers Color (Section 09 06 00 or a blank) + Extra Materials (spare tiles and carpet) + Delivery, Storage, and Handling (temperature sentence that, as printed, asks for storage “less than” the lower limit) + Manufacturer’s and Installer’s Warranties (direct from the manufacturer; fixed periods) + product data requested inside Part 3 General Requirements + Protection + base scheduleDoes the base schedule show the base material and style for each athletic room and does Part 3 cover installing a vinyl base if one is kept, does colour come from one source, has the storage sentence been corrected to a range, and are the warranty terms and extra materials what the owner can accept and store?

Worked example: a fitness center with a weight room, an indoor track, and a multi-purpose room

Illustrative example: a base fitness center has a weight room, an indoor running track around a mezzanine, and a multi-purpose room used for aerobics and volleyball. The issued Section 09 65 66 keeps rubber composition tile, rubber poured-in-place flooring, and urethane poured-in-place flooring, all marked “Type A”, and the fixed F2772 performance level. The finish plan tags all three rooms “RAF”, the slab joint plan runs an expansion joint across the multi-purpose room, the equipment plan shows volleyball sockets with no anchor plate detail, the track section shows no flooring thickness, and the game line plan exists for the multi-purpose room only.

Ask the specifier to give each kept type its own symbol and key it on the finish plan, to state the F2772 classification each room needs, to give a thickness for the poured rubber track, and to move the game line and anchor plate drawing requirement into Shop Drawings. Ask the structural engineer whether the expansion joint can move to the room perimeter as the Part 3 note advises. Ask the architect to detail the volleyball anchor plates through the urethane floor and to coordinate them with the Division 11 equipment section.

Avoid a false conflict

Section 09 65 66 covers resilient athletic floors. General resilient tile and sheet flooring follows Section 09 65 00 and the resilient flooring guide, carpet outside athletic rooms follows Section 09 68 00, wood gymnasium floors follow Sections 09 64 66 or 09 64 29, the slab and its joints follow Section 03 30 00, sealants follow Section 07 92 00, colours follow Section 09 06 00, athletic equipment and its anchors follow Division 11, and the adopted building and fire codes govern interior floor finish classification, so check those before calling a requirement missing. Some of the section’s own wording needs resolving: the storage temperature sentence is missing a “not”, the warranty emission rate has no basis, poured rubber has no thickness, EN and DIN tests are cited without designations, one performance level is fixed while another paragraph defers to the project, fire performance names no test, two properties have no test or unit, the game line drawing requirement sits in one tile paragraph, and Part 3 installs only a rubber base. Ask the specifier which wording the project intends before treating a difference as a design conflict.

When requirements disagree, follow the project’s document-control and clarification process. Do not assume that drawings always override specifications, or the reverse. Identify the exact sources and request an authorized decision.

Close the issue across the affected documents

Record the location or tag, drawing and specification references, issue dates, observed difference, and the decision needed. Assign an owner and keep the item open until the response identifies the governing requirement. Check the revised drawings and specification references together; a response email alone may leave the issued package inconsistent.

For the overall process, use the guide to drawing and specification conflicts. Mark an inapplicable checklist row with a reason, and distinguish a verified correction from a question that still needs design information.

Where Groundbook fits

Groundbook’s drawing and specification review helps investigate potential disagreements in the documents you supply. Include the relevant specification sections and drawing references, then verify the cited evidence with the responsible reviewers before acting on a finding.

Questions, answered

FAQs

What should a resilient athletic flooring specification review compare?

Compare floor types and finish plan keys, athletic performance and shock absorption, fire performance and indoor air quality, slab joints and moisture, thickness, underlay, and floor heights, seams, borders, and installers, game lines, anchor plates, and equipment, and base, colour, storage, warranty, and protection.

Which rooms does UFGS 09 65 66 have in mind?

The notes of the current UFGS 09 65 66 Resilient Athletic Flooring on WBDG recommend its systems for indoor athletic rooms such as weight rooms, running tracks, recreational areas, aerobic centers, and multi-purpose gym floors, and say hardwood is preferable for basketball, handball, and racquetball courts. UFGS numbers are DoD guide specification numbers, not universal MasterFormat titles, and your project’s issued specification governs.

How is this different from the resilient flooring and wood strip flooring pages?

UFGS 09 65 00 covers general resilient tile and sheet flooring, and UFGS 09 64 29 covers wood strip and plank floors and court walls. UFGS 09 65 66 covers rubber, vinyl, urethane, and carpet floors built for sport, with athletic performance testing, poured-in-place systems, shock-absorbing underlay, and game lines, so on one project check that each athletic room is keyed to one of these sections.

Can Groundbook check a weight room floor against Section 09 65 66?

Groundbook compares the drawing set with the specification sections and reference documents you upload, such as your issued Section 09 65 66, Sections 09 06 00 and 03 30 00, the equipment plan, the flooring manufacturer’s data, and licensed standards you hold, and returns potential conflicts with links to the source pages. It has no built-in code library and does not select flooring systems, test performance, rate finishes, certify compliance, or approve submittals. Each finding is a question for the architect, the specifier, the structural engineer, or the contracting officer.

Bring your next set into focus

Set up a review or talk through your project with our team.

Check your weight room and track floors against the spec